Battery & Solar Guide
9 min read
• Updated 2026-10-23

Van and RV Solar + Battery Sizing: How Many Panels and How Much Battery for Your Daily Use

Size a van or RV solar and battery system from your real daily watt-hours: panels from peak sun hours and derating, battery from usable depth of discharge and inverter loss, and charge controller from array watts.

Step-by-Step Procedure

1

List your loads and add up daily watt-hours

List each load, its watts and its hours per day, then multiply and add. For example, a 12 V fridge at about 400 Wh per day, lights 100 Wh, a laptop 150 Wh and a fan 100 Wh total about 750 Wh, and a small margin brings a planning total to about 1,000 Wh per day. Do not size from panel wattage alone; size from daily energy.

2

Size the solar array from peak sun hours and derating

Divide daily watt-hours by peak sun hours, then divide again by a derating factor of about 0.75 to 0.78 for real-world losses from temperature, wiring, controller efficiency and imperfect angle. For 1,000 Wh per day at 4 peak sun hours: 1,000 / (4 x 0.75) = 333 W, so round up to about 400 W of panels, for example two 200 W panels. Peak sun hours change with location and season, so winter sizing needs a lower value.

3

Size the battery from usable energy, not nameplate energy

A battery's nameplate watt-hours are not all usable. For a lithium iron phosphate battery, plan on about 80% usable depth of discharge, and for lead-acid about 50%. Also allow for inverter loss of about 10%. For 1,000 Wh per day with one day of autonomy: 1,000 / (0.80 x 0.90) = 1,389 Wh nominal, which is about 116 Ah at 12 V. A 200 Ah 12 V lithium battery gives more margin for cloudy days and winter, as shown in the worked example.

4

Size the charge controller from array watts

For an MPPT controller, divide array watts by battery voltage and multiply by 1.25. For a 400 W array on a 12 V battery: 400 / 12 = 33.3 A, x 1.25 = 41.7 A, so use a 50 A controller (the next standard size up). Check the controller's maximum input voltage against the panels' cold-weather open-circuit voltage as well.

5

Check DC wiring, fusing and voltage drop

Keep 12 V runs short and thick, because voltage drop bites hardest at low voltage. Fuse each major circuit close to the battery, use a battery monitor or shunt so you can see real state of charge, and treat any fixed or mains-connected work as a job for a qualified installer. This guide is a planning estimate for a leisure system, not a substitute for product manuals or local safety rules.

Worked Practical Example

1,000 Wh per day, 4 peak sun hours, 12 V system

A van using about 1,000 Wh per day, with 4 peak sun hours in the planning season.

  • •Solar: 1,000 Wh / (4 peak sun hours x 0.75 derating) = 333 W, round up to 400 W of panels
  • •Battery minimum: 1,000 Wh / (0.80 usable x 0.90 inverter efficiency) = 1,389 Wh nominal
  • •Battery minimum at 12 V: 1,389 / 12 = 116 Ah, so a 120 Ah battery is the bare minimum
  • •Recommended with margin: 12 V 200 Ah lithium, 2,400 Wh nominal, about 1,920 Wh usable at 80%, about 1,728 Wh delivered after inverter loss
  • •Charge controller: 400 W / 12 V x 1.25 = 41.7 A, so a 50 A MPPT controller
✓ Planning result: about 400 W of solar, a 12 V 200 Ah lithium battery for margin, and a 50 A MPPT controller for a 1,000 Wh per day van system at 4 peak sun hours.

Common Mistakes to Avoid

  • ✕Confusing panel watts with daily watt-hours: a 400 W panel does not give 400 Wh in an hour unless conditions are ideal.
  • ✕Using nameplate battery capacity as usable capacity, especially with lead-acid at 50% usable depth of discharge.
  • ✕Forgetting inverter loss and controller derating, then wondering why the battery runs flat early.
  • ✕Sizing for summer sun hours and then running short in winter, when peak sun hours are much lower.

Frequently Asked Questions

How many solar panels do I need for a van?

It depends on your daily watt-hours and your peak sun hours. Divide daily watt-hours by (peak sun hours x 0.75) to get array watts, then round up to standard panel sizes. A 1,000 Wh per day van at 4 peak sun hours plans to about 400 W.

How long will a 100 Ah lithium battery run a 12 V fridge?

A 100 Ah 12 V lithium battery holds about 1,200 Wh nominal and about 960 Wh usable at 80% depth of discharge. At about 400 Wh per day for a fridge alone, that is roughly two days before other loads and inverter losses, so treat it as a planning estimate, not a guarantee.